Day

February 9, 2011
Company: Vital Images Inc.Date of Enforcement Report 2/2/2011 Class ll: PRODUCT Vital, Vitrea fX and Vitrea Enterprise Suite fX Model number: Vitrea fX 2.1, fX 3.0, and fX 3.1 Vitrea Enterprise Suite (VES) fX 1.2 and VES fX 1.3 The Vitrea 4D CT Brain Perfusion option is intended for post processing based on dynamic CT...
Read More
Company:Images, Inc., Date of Enforcement Report 2/9/2011 Class ll: PRODUCT Vital Connect 4.0 & 4.1, radiological image processing software A Medical diagnostic software system intended to process, analyze, review, and distribute multi-dimensional digital images acquired from a variety of imaging devices including: CT MR, CR/DR/DX, SC, US, NM, PET, XA and RF, etc. Vital connect...
Read More
Company: Varian Medical SystemsDate of Enforcement Report 2/2/2011 Class ll: PRODUCT 4D Integrated Treatment Console (4DITC); All versions up to and including 8.8.17 Designed to assist the operator of a radiation device in providing accurate treatment set-ups for each patient by monitoring set up parameters and preventing the radiation therapy device from commencing irradiation while...
Read More
Company: Varian Medical Systems.Date of Enforcement Report 1/26/2011 Class ll: PRODUCT Varian Medical Systems, Eclipse Client software versions with build numbers from 7.3.10 through 8.6.15 (i.e. excluding 8.6.17); Model Number: H48; Radiation Treatment Planning System. Recall Z-0911-2011 REASON Possible incorrect dose calculation: An anomaly in certain Eclipse versions where, under certain specific sequences of user...
Read More
Company: Teco Diagnostics.Date of Enforcement Report 2/2/2011 Class ll: PRODUCT 1) Teco Diagnostics Uritek TC-101 Urine Analyzer, Catalog Number: TC-101 The Uritek TC-101 (TC-101) urine chemistry analyzer is a semi-automated analyzer for urine chemistry analysis. This device has been manufactured and developed with advanced scientific technology of modern microprocessors, optics and electronics. The apparatus uses...
Read More
Company: Impac Medical Systems Inc., .Date of Enforcement Report 2/9/2011 Class ll: PRODUCT SEQUENCER for Mosaiq interfaced to Electa SL75-5 machines. Sequencer Verify and Record System is to assist in the process of patient treatment on a radiotherapy treatment machine with software control. Recall # Z-1029-2011. REASON Computer interface is defected. Computer based verification system...
Read More
Company: Impac Medical Systems Inc., .Date of Enforcement Report 2/9/2011 Class ll: PRODUCT SEQUENCER component of MOSAIQ versions 1.30 (all builds), 1.40 (all builds), 1.50 (all builds), 1.60 (all builds), and 2.0 (all builds). The intended use of SEQUENCER (a verification system) is to assist in the process of patient treatment on a radiotherapy treatment...
Read More
Company: Philips Healthcare Inc.Date of Enforcement Report 2/2/2011 Class ll: PRODUCT Physiological Monitoring, Patient Monitor M31250 Information Center Local Database Releases A, B, E.01, G, H, J, K, L, & M of Philips IntelliVue Information Center Software used in conjunction with PAS-210 Kit Remote Active Speakers. The intended use of the Information Center Software is...
Read More
Company: Philips Healthcare Inc.Date of Enforcement Report 2/2/2011 Class ll: PRODUCT Philips IntelliVue Clinical Information Portfolio (ICIP), Clinical Management System Software Version D.00 through D.03. Recall # Z-0414-2011. REASON Software: Scheduling function of the Philips Intellivue Clinical Information Portfolio Releases D.00 through D.03. Edits to a scheduled even frequency order may result in pending interventions...
Read More
Company: Abbott Point of Care Inc.Date of Enforcement Report 2/9/2011 Class ll: PRODUCT i-STAT Level 2 Control Value Assignment Sheets Human Consumption. a) Abbott List Number: 06F13-01; b) Abbott List Number: 025715. Recall # Z-1020-2011. REASON Three i-STAT Level 2 Control Value Assignment Sheets and the i-STAT CLEW A20 Software System Manual Update CD contain...
Read More
Company: GE Healthcare, LLC.Date of Enforcement Report 2/2/2011 Class ll: PRODUCT GE Healthcare Transport Pro Monitor with the CARESCAPE” Patient Data Module. Recall # Z-0363-2011. REASON Transport Pro Monitor stops communication with the CARESCAPE Patient Data Module (PDM) after 414 days of continuous run time. This time will equate to different amounts of real time...
Read More
Company: Accuray Inc.Date of Enforcement Report 2/9/2011 Class ll: PRODUCT CyberKnife Treatment Planning System, a subsystem of the CyberKnife Robotic Radiosurgery System, with MultiPlan Treatment Planning System Software version 3.5 Medical charged-particle radiation therapy system, intended for treatment planning and image-guided stereotactic radiosurgery and precision radiotherapy of lesions, tumors and conditions anywhere in the body...
Read More
Company: Accuray Inc..Date of Enforcement Report 2/9/2011 Class ll: PRODUCT Radiation therapy device. Medical charged particle radiation therapy system with software version. Model Numbers: Multi Plan Treatment Planning System, Software version 3.0, 3.1, 3.5.0, and 3.5.1. For the treatment planning and image guided radiosurgery and precision radiotherapy of lesions, tumors and conditions anywhere in the...
Read More
Company: Radiometer America Inc. Date of Enforcement Report 2/9/2011 Class ll: PRODUCT ABL90 FLEX Blood Analyzer Part Number: 393-090. Intended for use by trained technologists, nurses, physicians and therapists and for use in a laboratory environment, near patient or point-of-care setting. Also, Intended for in vitro testing of samples of heparinized whole blood. Recall #...
Read More

SoftwareCPR Training Courses:

IEC 62304 and other emerging standards for Medical Device and HealthIT Software

Our flagship course for preparing regulatory, quality, engineering, operations, and others for the activities and documentation expected for IEC 62304 conformance and for FDA expectations. The goal is to educate on the intent and purpose so that the participants are able to make informed decisions in the future.  Focus is not simply what the standard says, but what is meant and discuss examples and approaches one might implement to comply.  Special deep discount pricing available to FDA attendees and other regulators.

3-days onsite with group exercises, quizzes, examples, Q&A.

Instructor: Brian Pate

Next public offering:  TBD

Email training@softwarecpr.com to request a special pre-registration discount.  Limited number of pre-registration coupons.

Registration Link:

TBD

 


 

Being Agile & Yet Compliant (Public or Private)

Our SoftwareCPR unique approach to incorporating agile and lean engineering to your medical device software process training course is now open for scheduling!

  • Agile principles that align well with medical
  • Backlog management
  • Agile risk management
  • Incremental and iterative software development lifecycle management
  •  Frequent release management
  • And more!

2-days onsite (4 days virtual) with group exercises, quizzes, examples, Q&A.

Instructors: Mike Russell, Ron Baerg

Next public offering: March 7 & 28, 2024

Virtual via Zoom

Registration Link:

Register Now

 


 

Medical Device Cybersecurity (Public or Private)

This course takes a deep dive into the US FDA expectations for cybersecurity activities in the product development process with central focus on the cybersecurity risk analysis process. Overall approach will be tied to relevant standards and FDA guidance documentation. The course will follow the ISO 14971:2019 framework for overall structure but utilize IEC 62304, IEC 81001-5-1, and AAMI TIR57 for specific details regarding cybersecurity planning, risk characterization, threat modeling, and control strategies.

2-days onsite with group exercises, quizzes, examples, Q&A.

Instructor: Dr Peter Rech, 2nd instructor (optional)

Next public offering:  TBD

Corporate Office

15148 Springview St.
Tampa, FL 33624
USA
+1-781-721-2921
Partners located in the US (CA, FL, MA, MN, TX) and Canada.