Tag

recall

Software Recall

Company: St Jude Medical, Cardiac Rhythm Management Division Date of Enforcement Report:3/3/2020 Class II PRODUCT Ellipse, Tiered-therapy Cardioverter/Defibrillator, REF (UDI/GTIN): CD1377-36QC (05414734507646), CD2411-36C (05414734507585), CD1277-36 (05414734506045), CD1377-36C (05414734507622), CD2277-36Q (05414734505932), CD2377-36QC (05414734507523), with Merlin Patient Care System with software model 3330 Recall Number: Z-1351-2020 REASON Past updates to programmers and transmitters may lead some implantable...
Read More
Company: Siemens Medical Solutions USA, Inc Date of Enforcement Report: 3/3/2020 Class II PRODUCT COHERENCE Oncologist, Model Nos. 07333680 & 07351898 Recall Number: Z-1346-2020 REASON A potential safety issue arises when an offset calculation is followed by a filter operation; correcting the image alignment after this sequence will result in incorrect offset values which could...
Read More
Company: Siemens Medical Solutions USA, Inc Date of Enforcement Report: 2/26/2020 Class II PRODUCT Luminos dRF Max, model no. 10762471 – Product Usage: Luminos dRF Max is a device intended to visualize anatomical structures by converting an X-ray pattern into a visible image. The system has medical applications ranging from gastrointestinal examinations to cranial, skeletal,...
Read More
Company: Philips Medical Systems Gmbh, DMC Date of Enforcement Report: 2/26/2020 Class II PRODUCT CombiDiagnost GCF, Software v. 1.0.5, Product Code 709030 – Product Usage: Xray system, diagnostic, fluoroscopic, general purpose. Recall Number: Z-1328-2020 REASON When using the Table Up/Down button, the system may experience Error 80, which locks the geometry in that specific state,...
Read More
Company: Siemens Healthcare Diagnostics, Inc. Date of Enforcement Report: 2/26/2020 Class II PRODUCT ADVIA Chemistry CardioPhase High Sensitivity C-Reactive Protein (hsCRP) Calibrator – product Usage: For in vitro diagnostic use in the calibration of ADVIA¿ Chemistry systems for the CardioPhase¿ hsCRP assay. Recall Number: Z-1260-2020 REASON Atellica and ADVIA hsCRP calibrator accuracy has drifted away...
Read More
Company: Philips Respironics, Inc. Date of Enforcement Report: 2/26/2020 Class I PRODUCT Trilogy EVO Ventilator, International, Model Number IN2110X15B Trilogy Evo is intended for pediatric through adult patients weighing at least 2.5 kg. The ventilator can measure, display, record, and alarm SpO2, FiO2, CO2, and Pulse Rate data when integrated with the appropriate accessories. Recall...
Read More
Company: Dexcom Inc Date of Enforcement Report: 2/12/2020 Class II PRODUCT Dexcom Receiver, REF: MT22719, (Black, Pin, Blue), Rx Only, containing software version SW10617 and revision 4.0.1.048 – Product Usage: A non-adjunctive invasive glucose sensor is intended to determine glucose levels, and the direction and rate of change of glucose levels in people with diabetes....
Read More
Company: Degania Silicone, Ltd. Date of Enforcement Report: 1/22/2020 Class II PRODUCT Medline Thermistor Foley Catheter 14 FR 5-10 ml, non sterile Catalog Number: 102201101463MD {Medline code 55346) Monitor urinary output and bladder temperature in addition to facilitating urine drainage. Recall Number: Z-0809-2020 REASON Temperature deviation did not meet release specifications. RECALLING FIRM/MANUFACTURER Degania Silicone,...
Read More
Company: St Jude Medical, Cardiac Rhythm Management Division Date of Enforcement Report: 1/22/2020 Class II PRODUCT Merlin PCS Programmer software model 3330, used with Confirm Rx Insertable Cardiac Monitor (ICM), Model DM3500, Sterile. The firm name on the label of the ICM is St. Jude Medical Cardiac Rhythm Management Division, Sylmar, CA. – Product Usage:...
Read More
Company: GE Healthcare, LLC Date of Enforcement Report: 1/22/2020 Class I PRODUCT CARESCAPE Respiratory Module E-sCO Recall Number: Z-0754-2020 CARESCAPE Respiratory Module E-sCOVX Recall Number: Z-0755-2020 CARESCAPE Respiratory Module E-sCAiO Recall Number: Z-0756-2020 CARESCAPE Respiratory Module E-sCAiOV Recall Number: Z-0757-2020 CARESCAPE Respiratory Module E-sCAiOE Recall Number: Z-0758-2020 CARESCAPE Respiratory Module E-sCAiOVE Recall Number: Z-0759-2020 Airway...
Read More
Company: RAYSEARCH LABORATORIES AB Date of Enforcement Report: 1/1/2020 Class II PRODUCT RayStation stand-alone software treatment planning system, Model Numbers 4.0, 4.5, 4.7, 4.9, 5.0, 6.0, 6.1, 6.2, 6.3, 7.0, 8.0, 8.1, 9.0 – Product Usage: RayStation is a software system designed for treatment planning and analysis of radiation therapy. The treatment plans provide treatment...
Read More
Company: GE Healthcare, LLC Date of Enforcement Report: 1/1/2020 Class II PRODUCT ApexPro Telemetry System – Product Usage: The ApexPro Telemetry System is intended for use under the direct supervision of a licensed healthcare practitioner. The system is designed to acquire and monitor physiological data for ambulating patients within a defined coverage area. The system...
Read More
Company: LivaNova USA Inc Date of Enforcement Report: 1/1/2020 Class I PRODUCT VNS Therapy, SenTiva, Model # 1000, (01)05425025750405, Rx Only for vagal nerve stimulation (VNS) therapy Recall Number: Z-0561-2020 REASON Certain Model 1000 generators (SN = 100,000) have experienced unexpected device resets, which resulted in disablement of therapy. Fourteen (14) complaints have been reported....
Read More
Company: Carl Zeiss Meditec, Inc. Date of Enforcement Report: 12/25/2019 Class II PRODUCT VisuMax Software Version 2.10.13 with activated Software-Module ReLEx (SMILE) option used in conjunction with the VisuMax Femtosecond Laser System for Refractive Correction. Catalog Number 0000000-1345-518 Product Usage: The VisuMax Femtosecond Laser is a precision ophthalmic surgical laser designed for the creation of...
Read More
Company: GE Healthcare, LLC Date of Enforcement Report: 12/25/2019 Class II PRODUCT Aestiva MRI, Model Numbers: a) 1006-9310-000 b) 1006-9110-000 c) 1006-9023-000 d) 1006-9028-000 e) 1006-9310-000-305077 f) 1006-9310-000-015243 g) 1006-9310-000-017602 h) 1006-9310-000-103785 I) 1006-9310-000-025109 j) 1006-9310-000-009650 k) 1006-9310-000-015224 l) 1006-9310-000-031881 m) 1006-9310-000-031854 n) 1006-9310-000-026571 Recall Number: Z-0114-2020 REASON Certain Aespire and Aestiva Anesthesia Systems were...
Read More
Company: Smiths Medical ASD Inc. Date of Enforcement Report: 12/16/2019 Class I PRODUCT Medfusion Syringe Pump, Model 4000. The Model 4000 pump is a small, lightweight and portable syringe infusion pump. The pump offers a variety of delivery modes programmable to meet specific patient care needs. Recall Number: Z-0610-2020 REASON There is an anomaly in...
Read More
Company: Siemens Medical Solutions USA, Inc Date of Enforcement Report: 11/20/2019 Class II PRODUCT Software versions syngo CT VB20 running on the following Siemens SOMATOM CT Scanner. SOMATOM Force (Model #10742326), SOMATOM Definition As (Model #8098027), SOMATOM Definition Edge (Model #10590000), SOMATOM Definition Flash (Model #10430603), SOMATOM Drive (Model #10431700), SOMATOM Confidence (Model #10590100), and...
Read More
Company: Draegar Medical Systems, Inc. Date of Enforcement Report: 11/20/2019 Class II PRODUCT Infinity M300 telemetry monitoring device Software versions VG2.3.1 and lower, Model Numbers MS25755, MS26076, MS26031, MS18623, MS22862, MS25301 Recall Number: Z-0372-2020 REASON The devices have potential cybersecurity vulnerabilities, which can include Distributed Denial of Service (DDoS), Spoofing, and Tampering. RECALLING FIRM/MANUFACTURER Draegar...
Read More
Company: Abiomed, Inc. Date of Enforcement Report: 11/13/2019 Class II PRODUCT lmpella CP with Smart Assist, Model Number: 0048-0003. Left heart support blood pump, for Use During Cardiogenic Shock and High-Risk PCI Recall Number: Z-0345-2020 REASON This one pump shipped with incorrect pump programming, the initial production working version of the program. The pump would...
Read More
Company: Baxter Healthcare Corporation Date of Enforcement Report: 11/13/2019 Class II PRODUCT Prismaflex Control Unit, software versions below 7.21 Recall Number: Z-0276-2020 REASON Communication error alarms may result in interruption of therapy, delay in therapy, or blood loss due to non-restitution of blood in the extracorporeal circuit. RECALLING FIRM/MANUFACTURER Baxter Healthcare Corporation on 10/4/2019. Voluntary: ...
Read More
Company: Medtronic Inc. Date of Enforcement Report: 11/13/2019 Class I PRODUCT Minimed Model 500 Remote Control for use with the MiniMed 508 Insulin Pump, model number MMT-500RU. Recall Number: Z-0177-2020 REASON There is a potential security vulnerability related to the use of the remote controller accessories with the insulin pumps. RECALLING FIRM/MANUFACTURER Medtronic Inc. on...
Read More
Company: Insulet Corporation Date of Enforcement Report: 11/13/2019 Class II PRODUCT Omnipod DASH Insulin Management System, Product Catalog Number 18239 M/D: PDM USA1 D001 MG USA1 Recall Number: Z-0347-2020 REASON There is a potential for a communication interruption following a bolus command that may result in inaccurate information presented in insulin on board (IOB), last...
Read More
Company: Zimmer Biomet Date of Enforcement Report: 11/7/2019 Class I PRODUCT The ROSA Brain device is a robotic platform that assists neurosurgeons in positioning medical instruments or implants during surgery. The device is composed of a compact robotic arm and a touch screen mounted on a stand. Different types of instruments may be attached to...
Read More
Company: Medical Components, Inc dba MedComp Date of Enforcement Report: 11/6/2019 Class II PRODUCT C3 Wave App, v. 2.0.5 Recall Number: Z-0222-2020 REASON When the iPad is updated with Apple iOS software version 12, the C3 application malfunctions. Upon launching a new procedure, the ECG waves do not appear on the screen, in surface or...
Read More
Company: GE Healthcare, LLC Date of Enforcement Report: 10/23/2019 Class II PRODUCT ApexPro Telemetry Server System. Also identified as Modification To: ApexPro Telemetry System and ApexPro FH Telemetry System – Product Usage: These systems are typically deployed in sub acute care areas in hospitals or clinical sites where patient mobility can enhance the effectiveness of...
Read More
Company: Abbott Laboratories, Inc Date of Enforcement Report: 10/16/2019 Class II PRODUCT Alinity S System, Part Number 06P16-01 Recall Number: Z-0111-2020 REASON Two software issues have been identified for the Alinity S System containing software version 2.0.0: Alinity’s Probe Wash: When Alinity’s CMV IgG Qualitative assay is run as the last assay on a sample,...
Read More
Company: WOM World of Medicine AG Date of Enforcement Report: 10/9/2019 Class II PRODUCT Aquilex Fluid Control System component: Bag deflector, REF AQL-100CBS Product Usage: Distends uterus with fluid during diagnostic and operative hysteroscopies. Recall Number: Z-2767-2019 REASON The deficit displayed by the pump can differ from the real deficit, leading potentially to patient risk....
Read More
Company: ELITech Group B.V. Date of Enforcement Report: 10/9/2019 Class III PRODUCT Viva-ProE Systems, Model # 6003-670, UDI: 03661540600357 – Product Usage: The ELITech Clinical Systems Selectra ProM is an automated clinical chemistry system intended for use in clinical laboratories. It is intended to be used for a variety of assay methods that have been...
Read More
Company: Elekta Inc Date of Enforcement Report: 10/2/2019 Class II PRODUCT Monaco RTP System, 5.40 Unity, radiation treatment planning system Product Usage: The Monaco system is used to make treatment plans for patients with prescriptions for external beam radiation therapy. The system calculates dose for photon, electron, and carbon treatment plans and displays, on-screen and...
Read More
Company: GE Healthcare, LLC Date of Enforcement Report: 10/2/2019 Class II PRODUCT Proteus XR/a (SlOK : K993090) Recall Number: Z-2449-2019 REASON Intermittently not receiving an audible exposure indication upon completion of an exposure on the Proteus stationary radiographic system. RECALLING FIRM/MANUFACTURER GE Healthcare, LLC on 8/9/2019. Voluntary:  Firm Initiated recall is ongoing. VOLUME OF PRODUCT...
Read More
Company: Vital Scientific N.V. Date of Enforcement Report: 10/2/2019 Class II PRODUCT V-Twin, Model # 6002-800, UDI: 03661540600180 Product Usage: An in-vitro diagnostic device, which is an automated chemistry analyzer, micro type, intended for clinical use in conjunction with certain materials to measure a variety of analytes, including applications in clinical chemistry, monitoring drugs of...
Read More
Company: Roche Diabetes Care, Inc. Date of Enforcement Report: 10/2/2019 Class II PRODUCT Accu-Chek Connect Diabetes Management App Recall Number: Z-2753-2019 REASON Users with Android OS 8.0 and above may be unable to transfer values obtained on their meter to the App. RECALLING FIRM/MANUFACTURER Roche Diabetes Care, Inc. on 5/3/2019. Voluntary:  Firm Initiated recall is...
Read More
Company: Smiths Medical ASD Inc. Date of Enforcement Report: 10/2/2019 Class II PRODUCT Medfusion Model 4000 Syringe Infusion Pump, with PharmGuard Server Software (PGS). Sold under the following names: MEDFUSION 4000 Pump V1.0; MEDFUSION 4000 Pump V1.1, v1.1.1, v1.1.2; MEDFUSION 4000 Pump V1.1, V1.1.1, V1.1.2; MEDFUSION 4000 Pump V1.5, V1.5.1; MEDFUSION 4000 Pump V1.5, V1.5.1;...
Read More
Company: CareFusion 303, Inc. Date of Enforcement Report: 9/11/2019 Class II PRODUCT Alaris EtCO2, Model 8300, UDI: 10885403830013, CareFusion for models 11634567 and 8300ADXeN933 Recall Number: Z-2443-2019 REASON Calibration; it has been determined that the capnographs may have been calibrated during manufacturing using a lower than specified concentration of CO2 RECALLING FIRM/MANUFACTURER CareFusion 303, Inc....
Read More
Company: SonarMed Inc Date of Enforcement Report: 9/11/2019 Class II PRODUCT SonarMed AirWave Monitor, Model Number M0001 Recall Number: Z-2450-2019 REASON Potential for the presence of two error codes which would make the monitor inoperable. RECALLING FIRM/MANUFACTURER SonarMed Inc. on 4/17/2017. Voluntary:  Firm Initiated recall is ongoing. VOLUME OF PRODUCT IN COMMERCE 16 units DISTRIBUTION...
Read More
Company: Siemens Medical Solutions USA, Inc Date of Enforcement Report: 9/11/2019 Class II PRODUCT syngo.CT software version VA48A_SP5.5 in the following SOMATOM computed tomography models: SOMATOM Definition Edge-Model #10590000; SOMATOM Definition AS Model #8098027; SOMATOM Definition Flash Model #10430603 Recall Number: Z-2440-2019 REASON SOMATOM Definition Edge, SOMATOM Definition AS, SOMATOM Definition Flash with software syngo.CT...
Read More
Company: Becton Dickinson & Co. Date of Enforcement Report: 9/11/2019 Class II PRODUCT BD Kiestra InoqulA Software Version 20.3.IVD automated specimen processing Catalog Number: 447202 Recall Number: Z-2438-2019 Recall Number: Z-2439-2019 REASON An anomaly is present in InoqulA / InoqulA+ software version 20.3, has the potential to cause a mismatch between a specimen and plate....
Read More
Company: Elekta, Inc. Date of Enforcement Report: 9/4/2019 Class II PRODUCT Monaco Radiation Treatment Planning System (RTP) System Recall Number: Z-2409-2019 REASON Monaco is displaying the Anatomy and Beam shift direction incorrectly on the Monaco Scan and Setup Reference Report and is DICOM exporting incorrect (Anatomy/Beam) shift directions. RECALLING FIRM/MANUFACTURER Elekta, Inc. on 8/23/2019. Voluntary: ...
Read More
Company: Phadia Ab Date of Enforcement Report: 9/4/2019 Class II PRODUCT Phadia” 1000 Model # 12-3800-01 Product Usage: The instrument is fully integrated and automated instrument including software for immunodiagnostic testing. The instrument is designed to handle all steps from sample and reagent handling to processing of results. Recall Number: Z-2397-2019 REASON Code 7-102 Liquid...
Read More
Company: Spectrum Medical Ltd. Date of Enforcement Report: 9/4/2019 Class I PRODUCT Quantum Pump Console Recall Number: Z-2238-2019 REASON Potential for Quantum Pump Console, part of the Quantum Perfusion Systems, to unexpectedly shut down while in use. RECALLING FIRM/MANUFACTURER Spectrum Medical Ltd. on 5/29/2019. Voluntary:  Firm Initiated recall is ongoing. VOLUME OF PRODUCT IN COMMERCE...
Read More
Company: Abbott Gmbh & Co. KG Date of Enforcement Report: 9/4/2019 Class II PRODUCT Alinity ci -series System Control Module, Part Number 03R70 01 Product Usage: The Alinity ci series System Control Module has a scalable design to provide full integration of clinical chemistry and immunoassay analysis. The Alinity ci series System Control Module includes...
Read More
Company: Agilent Technologies, Inc. Date of Enforcement Report: 9/4/2019 Class II PRODUCT MassHunter Quantitative Analysis Software, Version B.07.01, used with Triple Quadrupole Mass Spectrometers, models K6460 and K6420 Product Usage: A mass spectrometer for clinical use is a device intended to identify inorganic or organic compounds (e.g., lead, mercury, and drugs) in human specimens by...
Read More
Company: Qiagen Sciences LLC Date of Enforcement Report: 8/28/2019 Class II PRODUCT QIAsymphony SP SOW 5.0.3, software used with the QIAsymphony SP Instrument (The QIAsymphony SP instrument is designed to perform automated purification of nucleic acids-IVD) Model Number: 9001297 Product Usage: The QIAsymphony SP instrument is designed to perform automated purification of nucleic acids. It...
Read More
Company: Siemens Medical Solutions USA, Inc. Date of Enforcement Report: 8/28/2019 Class II PRODUCT ACUSON NX2 Diagnostic Ultrasound System, Model # 11284381, RX Only, Siemens Medical Solutions, containing software version VA10A, VA10B, VA11A, VA11B; UDI # 04056869030005 The ACUSON NX2 diagnostic ultrasound imaging systems are intended for the following applications: Cardiac, Fetal, Abdominal (including liver),...
Read More
Company: Radiometer America Inc Date of Enforcement Report: 8/28/2019 Class II PRODUCT ABL90 FLEX Analyzer REF 393090 UDI:05700693930909 Recall Number: Z-2320-2019 REASON Software Security; The action is being initiated because of software security vulnerabilities with the firm’s analyzer operating system, which may cause the device to shutdown or reboot resulting in delayed medical treatment. RECALLING...
Read More
Company: Luminex Corporation Date of Enforcement Report: 8/28/2019 Class II PRODUCT Luminex Aries M1 System Model: Aries M6V1 Aries Software v1.0 For In Vitro Diagnostic Use in clinical laboratories. Scanner Label/Labeling: JADAK JDK-2330 REV B 170512-017. Recall Number: Z-2292-2019 REASON An incorrect control board and firmware installed in some of the Hand Held Barcode Scanners...
Read More
Company: Siemens Medical Solutions USA, Inc Date of Enforcement Report: 8/21/2019 Class II PRODUCT SOMATOM Definition AS, Model Number 8098027 – Product Usage: Computed tomography systems intended to generate and process cross-sectional images of patients by computer reconstruction of x-ray transmission data. The images delivered by the system can be used by a trained physician...
Read More
Company: Fenwal Inc Date of Enforcement Report: 8/21/2019 Class II PRODUCT VOLUMAT MC AGILIA US, Infusion Pump, REF Z021135, software versions 1.7 and 1.9a Product Usage: The Volumat MC Agilia is a piece of transportable medical equipment intended to be used in healthcare facilities environment by healthcare trained professionals according to hospital protocols on adults,...
Read More
Company: Fenwal Inc Date of Enforcement Report: 8/21/2019 Class I PRODUCT VOLUMAT MC AGILIA US, Infusion Pump, REF Z021135, software versions 1.7 and 1.9a Product Usage: The Volumat MC Agilia is a piece of transportable medical equipment intended to be used in healthcare facilities environment by healthcare trained professionals according to hospital protocols on adults,...
Read More
Company: Philips North America, LLC Date of Enforcement Report: 8/14/2019 Class II PRODUCT Philips Azurion systems with software version R1.2 -Interventional Fluoroscopic X-ray system as follows: Azurion 3 M12, Azurion 3 M15, Azurion 7 B12, Azurion 7 B20, Azurion 7 M12, Azurion 7 M20 Models: 722063, 722064, 722067, 722068, 722078, 722079. Product Usage: The Azurion...
Read More
1 6 7 8 9 10 62

SoftwareCPR Training Courses:

IEC 62304 and other emerging standards for Medical Device and HealthIT Software

Our flagship course for preparing regulatory, quality, engineering, operations, and others for the activities and documentation expected for IEC 62304 conformance and for FDA expectations. The goal is to educate on the intent and purpose so that the participants are able to make informed decisions in the future.  Focus is not simply what the standard says, but what is meant and discuss examples and approaches one might implement to comply.  Special deep discount pricing available to FDA attendees and other regulators.

3-days onsite with group exercises, quizzes, examples, Q&A.

Instructor: Brian Pate

Next public offering:  TBD

Email training@softwarecpr.com to request a special pre-registration discount.  Limited number of pre-registration coupons.

Registration Link:

TBD

 


 

Being Agile & Yet Compliant (Public or Private)

Our SoftwareCPR unique approach to incorporating agile and lean engineering to your medical device software process training course is now open for scheduling!

  • Agile principles that align well with medical
  • Backlog management
  • Agile risk management
  • Incremental and iterative software development lifecycle management
  •  Frequent release management
  • And more!

2-days onsite (4 days virtual) with group exercises, quizzes, examples, Q&A.

Instructors: Mike Russell, Ron Baerg

Next public offering: March 7 & 28, 2024

Virtual via Zoom

Registration Link:

Register Now

 


 

Medical Device Cybersecurity (Public or Private)

This course takes a deep dive into the US FDA expectations for cybersecurity activities in the product development process with central focus on the cybersecurity risk analysis process. Overall approach will be tied to relevant standards and FDA guidance documentation. The course will follow the ISO 14971:2019 framework for overall structure but utilize IEC 62304, IEC 81001-5-1, and AAMI TIR57 for specific details regarding cybersecurity planning, risk characterization, threat modeling, and control strategies.

2-days onsite with group exercises, quizzes, examples, Q&A.

Instructor: Dr Peter Rech, 2nd instructor (optional)

Next public offering:  TBD

Corporate Office

15148 Springview St.
Tampa, FL 33624
USA
+1-781-721-2921
Partners located in the US (CA, FL, MA, MN, TX) and Canada.