Company: GE Healthcare, LLC Date of Enforcement Report: 11/29/2018 Class II: PRODUCT Patient Monitoring System used to monitor physiologic parameter data on adult, pediatric and neonatal patients. Recall Number: Z-0519-2019 (Dash 3000), Z-0520-2019 (Dash 4000), Z-0521-2019 (Dash 5000), Z-0522-2019 (Solar 8000i), Z-0523-2019 (Solar 8000M), Z-0524-2019 (Solar 9500) REASON The patient monitors may simultaneously restart as designed if all are connected...
Read More
Company: PerkinElmer Health Sciences Canada, Inc. Date of Enforcement Report: 11/28/2018 Class II: PRODUCT PerkinElmer QSight 210 MD Mass Spectrometer Simplicity 3Q MD v1.0 with Hot Fix 2 Software intended to identify compounds in human samples by ionizing the compound and separating the resulting ions. Part Number: BC004872 Recall Number: Z-0513-2019 REASON Under certain conditions...
Read More
Company: Synaptive Medical Inc. Date of Enforcement Report: 11/26/2018 Class II: PRODUCT BrightMatter Guide, Product Number SYN-0026, Versions: 1.5.0, 1.5.1 and 1.5.2 Product Usage: BrightMatter Guide can navigate a third-party port (NICO BrainPath device) by attaching Synaptive s custom Tracking Array to the port directly. As the BrainPath is navigable in two configurations (sheath only /...
Read More
Company: Tosoh Bioscience Inc Date of Enforcement Report: 11/19/2018 Class II: PRODUCT Tosoh AIA-900 immunoassay Analyzer Recall Number: Z-0485-2019 REASON A software issue may cause the liquid volume detection entries for 2nd and 3rd reagent bottles to be overwritten with the data from the 1st reagent bottle. Tosoh has released software version 2.51 (or later)...
Read More
Company: Voluntis Date of Enforcement Report: 11/16/2018 Class II: PRODUCT Insulia Diabetes Management Companion Recall Number: Z-0478-2019 REASON The firm identified an issue with the basal calculator identified on the Android version of the Insulia application. The bug could lead from low-impact to high-impact hypoglycemia depending on the circumstances. A new update of Insulia is...
Read More
Company: Invivo Corporation Date of Enforcement Report: 11/14/2018 Class II: PRODUCT Xper Flex Cardio Physiomonitoring System, Software version 1.6.0.0388 Recall Number: Z-0462-2019 REASON The Invasive Blood Pressure (IBP) numeric values will freeze on the display when any of the following functions are performed: change an IBP Site Label using the Site Label icon or the...
Read More
Company: GE Healthcare, LLC Date of Enforcement Report: 11/9/2018 Class II: PRODUCT Aisys CS2 Anesthesia System. Sold under the following product names: AISYS, AISYS 10.X TO 11.X UPGRADE KIT DUTCH, AISYS 10.X TO 11.X UPGRADE KIT ENGLISH, AISYS 10.X TO 11.X UPGRADE KIT ENGLISH FOR USA, AISYS 10.X TO 11.X UPGRADE KIT FRENCH, AISYS 10.X...
Read More
Company: Medtronic Inc. Date of Enforcement Report: 11/8/2018 Class II: PRODUCT Medtronic CareLink 2090 Programmer and Encore 29901 Programmer Recall Number: Z-0406-2019 (2090), Z-0407-2019 (29901) REASON Vulnerabilities have been identified in the SDN download process that may allow an individual with malicious intent to update the programmers with non-Medtronic software during an SDN download. RECALLING FIRM/MANUFACTURER Medtronic Inc.,...
Read More
Company: GE Healthcare, LLC Date of Enforcement Report: 11/2/2018 Class II: PRODUCT Centricity PACS-IW with Universal Viewer version 5.0.x with PACS-IW foundation displays medical images (including mammograms) and data from various imaging sources. Centricity Universal Viewer with PACS-IW foundation 6.0.x displays medical images (including mammograms) and data from various imaging sources. Recall Number: Z-0374-2019 (5.0.x), Z-0375-2019 (6.0.x) REASON...
Read More

SoftwareCPR Training Courses:

IEC 62304 and other Emerging Standards Impacting Medical Device Software

Being Agile & Yet Compliant

ISO 14971 SaMD Risk Management

Software Risk Management

Medical Device Cybersecurity

Software Verification

IEC 62366 Usability Process and Documentation

Or just email training@softwarecpr.com for more info.

Corporate Office

15148 Springview St.
Tampa, FL 33624
USA
+1-781-721-2921
Partners located in the US (CA, FL, MA, MN, TX) and Canada.