Mylan.
Product: pharmaceutical manufacturing facility
Date: 8/6/2015

Your firm failed to exercise appropriate controls over computer or related systems to assure that only authorized personnel can change master production and control records, or other records (21 CFR 211.68(b)).

Your Siemens computer-based BMS and NVPMS do not require passwords to access the network and servers. Your contractors? access is uncontrolled. Responsibilities for system administrators are undefined.

This violation is recurrent. On September 9, 2013, we cited your firm in Warning Letter 320-13-26 for failure to exercise appropriate controls over computer or related systems

FDA District Office: CDRH

Software Verification

Do you have gaps with IEC 62304 compliance or with FDA expectations for software verification?  We can help you quickly remediate gaps with unit verification including unit testing, code review, and static analysis, as well as integration and system verification testing.  Call us at 781-721-2921 or email office@softwarecpr.com to start a conversation.  We can provide estimates of cost and support your development tools.