Company: WELCH ALLYN PROTOCOL, INCDate of Enforcement Report: 9/12/01 Class: II RECALL NUMBER, PRODUCT AND CODE: Z-1049-1 Acuity Central Monitoring Stations with software versions 4.03.00, 4.03.01,4.03.02, 4.03.03, 4.03.04, and 4.03.05 when connected to VHF/UHF telemetry units CODES: software versions 4.03.00, 4.03.01, 4.03.02, 4.03.03, 4.03.04, and 4.03.05 REASON: Incorrect Visual Display MANUFACTURER/RECALLING FIRM: WELCH ALLYN PROTOCOL,...
Read More
Company: SIEMENS MEDICAL SYSTEMS, INC.Date of Enforcement Report: 9/12/01 Class: II RECALL NUMBER, PRODUCT AND CODE: Z-1105-1/Z-1107-1 Programmable Multi-Axis Controller (PMAC 2 Lite) circuit board installed in E.CAM Emission Imaging Computed Tomography Systems used for all common nuclear medicine proceduresCodes: a) Model 4380213 – E.CAM Gantry Single Head, serial numbers 0001 thru 2016 b) Model...
Read More
Compnay: Siemens Medical Systems, IncDate of Enforcement Report: 9/12/01 Class: II RECALL NUMBER, PRODUCT AND CODE: Z-0851-1 ICON Profile Processing Software used on the ICON P workstations designed for use with E.CAM Gamma Camera Systems to conduct cardiac Tomo and SPECT applications; 60195-5203. Codes: All E.CAM gamma cameras with the Profile option with ICON-P workstations...
Read More
Company: SANGUIN INTL., INCDate of Enforcement Report: 9/12/01 Class: II RECALL NUMBER, PRODUCT AND CODE: Z-1048-1 Medusa 2000 MED20SP Link Software Versions 1.2 and 1.3 The software Medusa 2000 is an interface link to the Ortho Summit Processor (OSP) which is a mass processing device for microplate based assays [tests for viral markers by ELISA]....
Read More
Company: GE Medical Systems, Information TechnologiesDate of Enforcement Report: 9/12/01 Class: II RECALL NUMBER, PRODUCT AND CODE: Z-1078-1 Clinical Information Center Software. The brand name was Marquette when the product was initially distributed. CODES: All devices with V.2 and later revisions of the software. REASON: Device can improperly restart resulting in no alarms or information...
Read More
Company: Dade Behring Marburg GMBH MarburgDate of Enforcement Report: 9/12/01 Class: II RECALL NUMBER, PRODUCT AND CODE: Z-0906-1 Behring Coagulation System (BCS) software CODES: Model OVIO03, Version 2.2 REASON: Leak of piston pump valve introduces air bubbles. MANUFACTURER/RECALLING FIRM: Dade Behring Marburg GMBH Marburg RECALLED BY: Dade Behring, Inc., Newark, DE, by letter. FIRM INITIATED...
Read More
Company: Applicare Medical ImagingDate of Enforcement Report: 9/12/01 Class: II RECALL NUMBER, PRODUCT AND CODE: Z-0857-1/Z-0858-1 RadWorks Software Version 5.1 with Software Patch 5 or 7, and RadWorks WebViewer Software Verion 5.1 running on RadWorks 5.1 Software Patch 5 or 7; picture archival and communications system; Applicare Medical Imaging B.V., Zeist, The Netherlands Codes: RadWorks...
Read More

SoftwareCPR Training Courses:

IEC 62304 and other Emerging Standards Impacting Medical Device Software

Being Agile & Yet Compliant

ISO 14971 SaMD Risk Management

Software Risk Management

Medical Device Cybersecurity

Software Verification

IEC 62366 Usability Process and Documentation

Contact Me

Fields marked with an * are required

Or just email training@softwarecpr.com for more info.

Corporate Office

15148 Springview St.
Tampa, FL 33624
USA
+1-781-721-2921
Partners located in the US (CA, FL, MA, MN, TX) and Canada.